Stimulatar Acupuncture 6 Channel Delux 2000

1208
Rs 9999
Stimulatar Acupuncture 6 Channel  Delux 2000
Stimulatar Acupuncture 6 Channel Delux 2000

Description :

Stimulatar Acupuncture 6 Channel  Delux 2000  which transmits pulsating currents of different wave patterns and frequencies through the Acupuncture needles o The MS-2000 Multiple Electro Stimulator has been designed for clinical use, r electrodes to human body. For therapeutic or anaesthesia purposes, the nervous or muscular system is excited or inhibited by means of stimulation and for physiotherapy stimulates muscles in stiffness, paralysis etc.This stimulator with its external battery box especially suitable for operation in places where the alternating current is not available. It is mainly used with therapeutic effect in the treatment of pain, paralysis of limbs, arthritis, strain, vomiting, sliming and the diseases which can be treated by Acupuncture, Acupressure or Physiotherapy. This stimulator is also suitable for applying acupuncture anaesthesia in surgical operations and reducing excess fat.A New Hard-Built Compact Design Having Scope of Following Application:- 

a) Electro-Acupuncture (Therapeutic).
b) Electro-Acupuncture (Anaesthesia).
c) T.E.N.S (Trans Electro-cutaneous Nerve Stimulator)
d) Physiotherapy Stimulator.
e) Acupressure treatment.
f) Fat reduction / Sliming.

Other Facilities:-a) Digital Time selector (10 min., 20 min. & 40 min.).
b) Auto Stop.
c) Time Resetting.
d) Manual Control (instead of Automatic).
e) A.C.  Main 220 V.D.C.9 V (6 x 1.5 Dry cells).
f) Two separate having a total 5 outputs.
g) Light indicators.
h) Three types of waves: Continuous (Regular Rhythm), Dense –Disperse (Quick –Slow), Discontinuous (Interrupted High Frequency).
i) Rotational Stimulation.

            
       Direction of Operation: - Acupuncture / Acupressure.
 01. Keep all output knobs at “o”.
02. Switch on the power supply either A.C. Main or Battery.
03. Select the Band Switch for Acupuncture / Acupressure.
04. Select the wave type (Continuous / D.D. / Discont).
05. Adjust the frequency of waves.
06. Insert the output plugs into holes of intensity control.
07. Connect output cord to points which you like to stimulate.
08. Be careful that positive & negative of each output do not touch each other anyway.
      09. Select the time setter (10/20/40 min.).
10.  Frequency can be controlled by “Frequency “, “Dense – Disperse & Discontinuous” regulator and the number of flashes shown by the pilot lamp is identical to the frequency of wave. 
 
   
          T .E. N. S.             Put T.E.N.S. plug into T.E.N.S. hole.
01. The –Patient will hold the metal rod in one hand.
02. The Doctor will put T.E.N.S. prob at various points. 1-2min. in each point, the patient will feel sensation at the point.
03. To control frequency use frequency control knob and for intensity use the intensity control knob of T.E.N.S.

             Physiotherapy
          01. Switch over to physiotherapy.
02 Apply Electro Conductive Rubber Plates on required places. To confirm the              operating may use the L.E.D. Put Rubber Plates plug into intensity hole and gradually rotate the output intensity control knob upto patient’s tolerance.
03.To control the frequency use the P/Th frequency control knob.     

Sliming:-01. Insert the output plugs into the hole of intensity control.
02. Place every pair of plates on any part of the body, specially in excess fat area. To get better stimulation apply electrolyte gel between skin and plate or you may apply saline (salty) water. Fix the plates by the Velcro band. Be careful that two plates do not touch each other.
03. Select the wave either D.D. or Discontinuous.
04. Gradually rotate the output intensity control knobs upto patient’s tolerance.
05. Select the time selector minimum for 20 min.   

Application:-01. For Therapy use :a) Continuous wave 5000-6000 minute. 
                  (b) D.D. wave 10-15 cycles par minute (one Dense and 
                   One Disperse phase jointly form one cycle), gives 
                   Massage like effect in muscular area. Applicable in
                   Joints and other areas also.

02. T.E.N.S.     : Continuous frequency 200-300 per minute. Effective  
                                      In superficial nature pain. Better accepted by children
                                      And patients who afraid of needles puncture.
 
03. Physiotherapy  : To stimulate muscles in stiffness, paralysis etc.

 Notes:-A) When the stimulator is not in use or under repair, turn the ‘Range Selector’ to ‘Off position’
B) Avoid any short-circuit of the needle clamps or the electrode plates when the ‘Range Selector’ is turn to the ‘on’ position otherwise consumption will be increased without voltage.
C) When charging batteries care must be taken to avoid polarity reversal otherwise the apparatus will be damaged.
D) If alternating current is used, after operation, pull-out the plug from the main socket in order to avoid spoiling the transformers due to overeating.
E) The therapeutic effect is closely related to the correct selection of point and the experience of the physician.                       

 

      उत्तेजना एक्यूपंक्चर 6 चैनल डेल्क्स 2000, जो एक्यूपंक्चर सुई के माध्यम से विभिन्न लहर पैटर्न और आवृत्तियों के स्पंदित धाराओं को प्रसारित करता है ओ एमएस -2000 मल्टीपल इलेक्ट्रो स्टिएम्युलेटर को नैदानिक ​​उपयोग के लिए तैयार किया गया है, मानव शरीर के लिए इलेक्ट्रोड को तैयार किया गया है। चिकित्सकीय या संज्ञाहरण के उद्देश्य के लिए, तंत्रिका या मांसपेशियों की प्रणाली उत्तेजना के माध्यम से उत्साहित या हिचक रही है और फिजियोथेरेपी के कारण कठोरता, पक्षाघात आदि में मांसपेशियों को उत्तेजित करती है। इस उत्तेजक व्यक्ति को अपने बाह्य बैटरी बॉक्स के साथ विशेष रूप से उन स्थानों पर ऑपरेशन के लिए उपयुक्त जहां वैकल्पिक चालू उपलब्ध नहीं है । यह मुख्य रूप से दर्द, उपचार के अंगों, गठिया, तनाव, उल्टी, स्लिमिंग और रोगों के उपचार में चिकित्सीय प्रभाव के लिए प्रयोग किया जाता है, जिन्हें एक्यूपंक्चर, एक्यूप्रेशर या फिजियोथेरेपी द्वारा इलाज किया जा सकता है। इस उत्तेजक तंत्र को सर्जिकल संचालन में एक्यूपंक्चर संज्ञाहरण लगाने और अतिरिक्त वसा को कम करने के लिए भी उपयुक्त है। एक नई हार्ड-बिल्ट कॉम्पैक्ट डिज़ाइन निम्नलिखित आवेदन का गुंजाइश है: -

ए) इलेक्ट्रो-एक्यूपंक्चर (चिकित्सीय)
बी) इलेक्ट्रो-एक्यूपंक्चर (एनेस्थेसिया)।
सी) टी.ई.एन.एस (ट्रांस इलेक्ट्रो-किकेनेटिक नर्व स्टिम्युलेटर)
डी) भौतिक चिकित्सा उत्तेजक।
ई) एक्यूप्रेशर उपचार
च) फैट कमी / स्लिमिंग

अन्य सुविधाएं: -ए) डिजिटल टाइम चयनकर्ता (10 मिनट, 20 मिनट और 40 मिनट)।
बी) ऑटो स्टॉप
ग) समय रीसेट
डी) मैनुअल कंट्रोल (बजाय स्वचालित)
ई) एसी मुख्य 220 वी डी डी 9 वी (6 एक्स 1.5 सूखी कोशिकाओं)।
च) दो अलग-अलग कुल 5 आउटपुट हैं।
छ) हल्की संकेतक
ज) तीन प्रकार की तरंगें: निरंतर (नियमित ताल), घने-दुश्मन (त्वरित-स्लो), अवरुद्ध (बाधित उच्च आवृत्ति)।
i) घूर्णी उत्तेजना

            
       ऑपरेशन की दिशा: - एक्यूपंक्चर / एक्यूप्रेशर
 01. "ओ" पर सभी आउटपुट घुंडी रखें
02. बिजली आपूर्ति या तो एसी मेन या बैटरी पर स्विच करें।
03. एक्यूपंक्चर / एक्यूप्रेशर के लिए बैंड स्विच चुनें
04. लहर प्रकार (निरंतर / डीडी / डिस्कन) चुनें।
05. तरंगों की आवृत्ति को समायोजित करें।
06. आउटपुट प्लग को तीव्रता नियंत्रण के छेद में डालें।
07. आउटपुट कॉर्ड को उन बिंदुओं से कनेक्ट करें, जिन्हें आप उत्तेजित करना पसंद करते हैं।
08. सावधान रहें कि प्रत्येक आउटपुट के पॉजिटिव और नेगेटिव किसी भी तरह से दूसरे को छूते नहीं हैं।
      09. समय सेटर चुनें (10/20/40 मिन।)
10. फ़्रिक्वेंसी को "फ़्रिक्वेंसी", "डेन्स - फैस्पेर एंड डिसकंटिएंस" नियामक द्वारा नियंत्रित किया जा सकता है और पायलट लैंप द्वारा दिखाए गए फ्लैश की संख्या लहर की आवृत्ति के समान है।